The ULD-40 is an ultrasonic detector designed for corona and arcing inspections for predictive maintenance in electric utilities. Corona effect occurs when electricity is discharges into the surrounding atmosphere form a high voltage source. Corona effects and electrical arcs in the air emit ultrasounds. The role of the ULD-40 consists of capturing emitted ultrasounds and of translating them into the audible range. This equipment is perfect for high voltage maintenance program.
The XDP II is a portable device for, online, factory and laboratory partial discharge measurement on electrical apparatus, or components. The XDP II can be used in accordance to IEC 60270. It records partial discharge measurements for computer analysis and diagnostic using the optional XDP II software for a PC. Using the appropriate accessories, the XDP II can be used in several applications.
The WRT-10D is a High performance & High accuracy winding resistance tester, this unit has a built in Demagnetisation circuit to automatically or manually, demagnetize the transformers and avoid situations where the Current Transformer could cause the protection circuits to trip when re-energizing.
The LCI helps in identifying energized electricity distribution power cables. (more)
The SPI-II is an instrument that enables remote identification of A-B-C electrical phases from all 50 and 60 Hz networks. Besides doing identification, the instrument enables verification of phase concordance and rotation in all safety and on any network points. This has become more and more essential whenever one wants to optimize the planning, the operation and the upkeep pf the electrical installations. No special cellular activation required; the customers use his cellular phone. (more)
The VCI-3 is a vocal cable identification and phasing system used during installation or maintenance works on de-energized three phase systems. (more)
The ADD allows on-line arresters default detection on power lines up to 69 kV (or up to 45kV phase-to-neutral). (more)
The ADD allows on-line arresters default detection on power lines up to 69 kV (or up to 45kV phase-to-neutral). (more)
The ADD allows on-line arresters default detection on power lines up to 69 kV (or up to 45kV phase-to-neutral). (more)
The PDS allows online partial discharge detection on underground cable accessories and equipment for security/maintenance purposes. This equipment is perfect for a high voltage predictive maintenance program. The PDS is very accurate to detect partial discharge on cable joints (XLPE/EPR type), switchgear, elbows, Cable Terminations, and more. (more)
The ULD-40 is an ultrasonic detector designed for corona and arcing inspections for predictive maintenance in electric utilities. Corona effect occurs when electricity is discharges into the surrounding atmosphere form a high voltage source. Corona effects and electrical arcs in the air emit ultrasounds. The role of the ULD-40 consists of capturing emitted ultrasounds and of translating them into the audible range. This equipment is perfect for high voltage maintenance program. (more)
The contact probe is an accessory of the ULD-40, our Ultrasonic Corona/Arcing Detector. The magnetic probe detects internal discharges caused by insulation breakdown in transformers, capacitors and switchgears. (more)
The XDP II is a portable device for, online, factory and laboratory partial discharge measurement on electrical apparatus, or components. The XDP II can be used in accordance to IEC 60270. It records partial discharge measurements for computer analysis and diagnostic using the optional XDP II software for a PC. Using the appropriate accessories, the XDP II can be used in several applications. (more)
The Differential Sensor with Double Spatula allows reducing ambient noise and handling when measuring partial discharge on MV/HV cable joints and elbows. Has been designed to detect partial discharge on insulated cable joints (XLPE/EPR type). The sensor is used with the XDP, an online Partial Discharge Detection System for underground cable accessories and equipment for security/maintenance purposes. (more)
The Differential Sensor with Double Spatula allow reducing ambient noise and handling when measuring partial discharge on MV/HV cable elbows. The sensor is used with the XDP, an online Partial Discharge Detection System for underground cable accessories and equipment for security/maintenance purposes. (more)
This Partial Discharge Measuring Kit, for distribution transformers, provides you with the easiest way to measure Partial Discharge in your single phase distribution transformers that are used on line up to 35kV (up to 25 kV phase-to neutral). (more)
The AL-40 allows a precise and easy quality control of welded electrical connections. The instrument measures the electrical resistance formed by the fusion of the weld with the conductors. The equipment has been designed specifically to test electrical connections/exothermic welds (Cadweld®) and it is the most accurate and competitive on the market in its category. (more)
The DOC-2000 can determine the presence of a short circuit and/or open circuit in a distribution transformer without disconnecting the seconday winding!! The unit is designed to be used with a hot stick which allows the user to have both feet on the ground at a safe distance. (more)
The DRM-10A micro-ohmmeter can be used to measure very low resistances which vary from 0,01µΩ to 200Ω. This is the most accurate on the market in its category. (more)
The DRM-40 micro-ohmmeter can be used to measure very low resistances which vary from 0,01 micro ohm to 200 ohms. This is the most accurate and competitive on the market in its category. It is used for quality control of smelting parts, control of mechanical joints, electrical connections, for inspection of contacts, circuit breakers, power fuses and more. (more)
The GET-401 is an easy-to-use and accurate Grounding Jumper Tester using an exclusive technique. The equipment guarantees your Protective Ground Set integrity. The resistance measurements guarantee that your Protective Grounding Sets are always in good condition. The Get-401 is ideal for a regular maintenance program. (more)
The CTTx2 & CTTx5 are rugged and easy to use current transformer testers, that offer Automatic & Manual testing modes. These instruments are designed to deliver fast and reliable measurements. (more)
The DOC-2000 can determine the presence of a short circuit and/or open circuit in a distribution transformer without disconnecting the seconday winding!! The unit is designed to be used with a hot stick which allows the user to have both feet on the ground at a safe distance. (more)
10 Amp Low Resistance Meter for electrical interconnections integrity testing The LRM-10's very low resistances measurments from 0,01 µΩ to 200Ω are targeted toward verifying the quality contact interfaces. (more)
Application and Operation Powers transformers are critical to Transmission and Distribution substations. In fact, losing a unit can have a major financial consequence. To protect your investment, use Acoustic Emission Testing. This technique is superior to electric methods for on-site tests. (more)
The WRT-10 is a high performance winding resistance tester designed for Power Transformer and large motor applications. (more)
The WRT-10D is a High performance & High accuracy winding resistance tester, this unit has a built in Demagnetisation circuit to automatically or manually, demagnetize the transformers and avoid situations where the Current Transformer could cause the protection circuits to trip when re-energizing. (more)
The SPI-II is an instrument that enables remote identification of A-B-C electrical phases from all 50 and 60 Hz networks. Besides doing identification, the instrument enables verification...
The XDP II is a portable device for, online, factory and laboratory partial discharge measurement on electrical apparatus, or components. The XDP II can be used in accordance to IEC 60270....
The DRM-10A micro-ohmmeter can be used to measure very low resistances which vary from 0,01µΩ to 200Ω. This is the most accurate on the market in its category.
Application and Operation Powers transformers are critical to Transmission and Distribution substations. In fact, losing a unit can have a major financial consequence. To protect your...