This Partial Discharge Measuring Kit, for distribution transformers, provides you with the easiest way to measure Partial Discharge in your single phase distribution transformers that are used on line up to 35kV (up to 25 kV phase-to neutral).
Partial Discharge diagnosis has been established as the most convincing technique for the evaluation of the insulation quality of MV/HV apparatus. Design, manufacturing or handling problems can be quickly identified using Partial Discharge testing and then improve design, increase network reliability and reduce operation cost by installing reliable components.
The XDP is our Partial Discharge Expert System and is the heart of the Distribution Transformer Partial Discharge Measuring Kit. The XDP is the most compact and portable Partial Discharge measurement system. The use of the XDP with a HF Capacitive Coupler allows you to measure the Partial Discharge activity in your distribution transformers. The equipment set up and connexions can be completed in minutes.
Other than the XDP Partial Discharge Expert System and the HF Capacitive Coupler, the kit includes a Variable Transformer, a noise suppressor to filter the low voltage AC input and a Calibrator. The Calibrator is used to inject a reference signal, in the complete test circuit, to calibrate the test set up in picoCoulomb. Calibration shall be made with each new test object, unless tests are made on a series of identical objects.
We are using an innovative technique without the need to use a high voltage source. It eliminates the usual complexity and high cost of similar test set. We apply low voltage at the distribution transformer output (secondary side). It generates the required high voltage for partial discharge measurement at the distribution transformer input (primary side). Using a variable transformer allows you to identify the partial discharge inception voltage and the level of this partial discharge activity.
Our Distribution Transformer Partial Discharge Measuring Kit is very easy to set up and install. It takes minutes to interconnect the components together and then to the distribution transformer to be tested. The HF Capacitive Coupler is small enough to be installed on the top of the distribution transformer. The complete kit can be easily moved to another location or stored when not used.
(pdf 113 KB)
(pdf 115 KB)
(pdf 117 KB)
1405 St-Jean Baptiste, suite 111
Québec, QC, Canada
Unit 7&8, ADF Centre
Vonkel Street, Saxenburg Park 2
Blackheath, Cape Town
P.O.Box 5858
Tygervalley
7536
Cape Town
Taman Palem Lestari Blok Q1-2
Cengkareng-Jakarta Barat
Jakarta, 11730 Indonesia
6FL., NO. 133, sec 5
Chung-Hsiao E RD.
Taipei, 11071 Taiwan
2/F Agile Centre, 248 Ext. A
Parada road, Fortune 5
Valenzuela City, 1442
Philippines
B-2305 Xingyuan International Building
222 Wangjing Xiyuan
Beijing, Chaoyang District 100102
PO Box 1796
Cleveland DC
QLD 4163 Australia
c/Agricultura, 34 (P.I. El Ceao)
27003 Lugo
P.O.Box: 41016
6308 Larnaca, Cyprus
RUA DEOCLECIANA, 77
Sao Paulo, SP 01106-030